+91 22 - 6144 8000 - 99

Cryogenic Valve

Oswal Cryogenic valves, except check valves are supplied with extended bonnet with a sufficient gas column length. Usually supplied by the user, to eliminate any chance of frosting of the packing area. The cryogenic valves are installed on applications involving the production, transport and storage of liquefied gases such as oxygen, nitrogen, argon, natural gas, hydrogen or helium down to -254ºC. The cryogenic valves are designed with compliance of ASME B16.34 and BS 6364. The cryogenic tests are performed in fully equipped in-house facilities, according to BS 6364.

Product Range - Cryogenic Valves

Valve Type Class Rating Size Range
Gate 150 2" to 36"
300 2" to 36"
600 2" to 24"
Globe 150 2" to 16"
300 2" to 16"
600 2" to 16"
Check 150 2" to 24"
300 2" to 24"
600 2" to 24"
Ball 150 2" to 24"
300 2" to 24"
600 2" to 24"

Standards

Design Standard ASME B16.34 / BS 6364
Testing Standard BS 6364
Face To Face ASME B 16.10
End Connection Flanged End - ASME B 16.5
Butt Weld End – ASME B 16.25
Pressure – Temperature Chart ASME B 16.34
Body material CF8M, CF8 and other low temperature steels